NEW GE LM6000PC Sprint, 47Mw/13.8kV, 60hz

GasTurbine Generator


( Item # = PG0156 ) NEW GE LM6000PC Sprint, 47Mw/13.8kV, 60hz

 47 MW LM6000 PC Sprints General Electric Gas Turbine GeneratorQuote request form for power generation Equipment - sets new with SCR  Winterized to - 20F - Natural Gas Only - Inlet Spray Mist Evaporative Cooling / Anti Icing Systems - exhaust heat exchangers - SCR's, NOx - 5 ppmvd at 15% O2, CO - 10 ppmvd at 15% O2, NH3 Slip - 10 ppmvd at 15% O2. - New factory warranty included

NEW GE LM6000PC Sprint, 47Mw/13.8kV, 60hz

47 MW LM6000 PC Sprints Gas Turbine Generator sets new with SCR  Winterized to - 20F (Natural Gas Only) Inlet Spray Mist Evaporative Cooling / Anti Icing Systems (exhaust heat exchangers).

SCR's, NOx - 5 ppmvd at 15% O2, CO - 10 ppmvd at 15% O2, NH3 Slip - 10 ppmvd
at 15% O2.
New factory warranty included.

Basic Scope

1.   LM6000 PC gas turbine engine with inlet bellmouth and screen.

Natural gas fuel system, complete and self-contained on the unit, with
connection to the base plate for customer's filtered, regulated fuel supply
at 675 psig+/-20 psig.

Generator, 13,800 volt, 60 Hz, 3600 RPM.  Low maintenance brushless
excitation system suitable for Class I, Group D, Div 2 areas. Neutral and
line cubicles with CT's, surge protectors and lightning arrestors.

4.  I-Beam base plates for turbine, generator and unit mounted accessories.

5.  Acoustical Enclosure for gas turbine and generator(90 dba).  Redundant
ventilation systems, and AC internal lighting.

6.  Multi stage air inlet filtration system for both gas turbine and
generator, including weather hoods, inlet screen, pre-filter, final barrier
filter, intake silencer, and standard ducting to plenum chamber. Filterhouse
ladders and platforms are included.

7.  Electro-hydraulic start system.

8. Separate oil systems for for gas turbine and generator, including duplex
filters, duplex water/oil coolers, stainless steel piping, and stainless
steel reservoirs.

9.  Unit control panel for indoor mounting in a controlled environment,
including microprocessor fuel management and sequencing system, generator
metering, Bently Nevada vibration monitoring, CRT annunciation of alarms and
shutdowns, and Ethernet/ Modbus interface to customer's DCS.

10.  I/O cubicle mounted on gas turbine enclosure.

11. 24V DC control system battery with dual battery chargers.
 

12.  Fire and gas detection and extinguishing system, serving both turbine
and generator compartments, complete with 24V DC battery and charger.

13.  ""Soak wash"" system for simple cycle service."

14.  Generator testing at factory to IEEE or IEC standards.  Gas turbine
"performance testing on factory dynamometer; full load string test"  (Note, for multiple unit
orders of identical equipment, first generator set for each site will be
full load string tested, additional gensets are factory tested at static
conditions).

15.  Six sets of drawing and data packages, O & M manuals.

16.  LM6000 gen set familiarization/basic operator training course, 5 days
at TX for up to 10 customer personnel.

Included Optional Equipment (These have been re-lettered to match the
current LM6000 Product Specification Manual)

Option C Alternate side location for piping connections and turbine removal.
Option D Alternate side termination, line side & neutral cubicles.
Option F Dual fuel system including piping, valves and controls.  Natural gas
with liquid fuel backup. (Units 1 & 2 Only)
Option G  Water injection metering system (Nox control with duel fuel
systems).  Simplex boost pump for peaking application, duplex pumps for base
load.  Includes Inlet strainer, valves and piping, controls and boost pump
skid.
Option J Sprint(Spray Inter cooling) Power Boost System.
Option M Inlet Air Chilling (cooling coils only)
Option Q Winterization Package to -20 deg F ambient.  Includes, inlet air
anti-icing, heat tracing and insulation of applicable unit mounted piping,
and enclosing and heating exposed instruments and equipment as specified by S
& S Energy products.
Option U Unit Motor Control Center.  Free standing lineup of motor controls
for motors suitable for indoor installation in optional modular control room
or other non-hazardous areas. Customer supplies the feeder breaker to
energize the MCC and interconnecting wiring to motor on main enclosure.
Option  (Old Option W, not in current manual).  Power system stabilizer for
electric generator (undefined scope)
 

Casinos

Craps Casino - Play Craps watch Animated Craps learn Craps Strategy

Poker Casino - Video Poker online, a poker game that can be played for free or real money

blackjack Casino - Blackjack Free game download or play for real money

Roulette Casino - different ways to place roulette bets in European Roulette

Keno Casino - Free Keno keno rule and keno strategy for playing internet keno

Slots Casino - slot machine casino has regular slot machine & free slot game download
 
 
Free Casino Games software Download

Diesel Generators
Steam Turbine Generators
Gas Turbine Generators
Power Generation Equipment Listing Form

Workers Compensation Insurance information board - Cork Board for Workers Compensation Insurance no affiliation with the Workplace Safety And Insurance Board of Ontario (WSIB)

Cork board for Workers Compensation Board - This site is a link to the Workers Compensation cork board not part of or approved by the Ontario WSIB Workplace Safety Insurance Board of Ontario WSIB

Province of Ontario Business Advisory Watch - This is a Ontario business advisory for clients and associate businesses with finical interest in the Province of Ontario or that are planing on investing in future business within Ontario

Worker Compensation, no part of Workplace Safety And Insurance Board WSIB  - This is a cork board for WSIB worker compensation, no part of or paid for WSIB Workplace Safety And Insurance Board Ontario Canada

Workers Compensation WSIB Cork Board - Workers Compensation information cork board isn't financed by WSIB Workplace Safety And Insurance Board of Ontario